City of Wilmington - Project Tracking
Home
|
Register or Login
Home
Projects
How To
Submittal Comments for Site Plan Version 7 at St Mark Mayfaire Entrance (20180652828)
Show all Submittals
Comment Number:
27859
Created By:
Aaron Reese
3/27/2019
Revised By:
Aaron Reese
3/27/2019
Title/Company:
City Arborist / City of Wilmington
Phone/Email:
910-341-0078 / aaron.reese@wilmingtonnc.gov
Comment Attachment:
No further comments.
Comment Number:
27860
Created By:
Brian Chambers
3/27/2019
Revised By:
Brian Chambers
3/27/2019
Title/Company:
Assistant Director - Planning & Development Department / City of Wilmington
Phone/Email:
(910)342-2782 / brian.chambers@wilmingtonnc.gov
Comment Attachment:
No further comments from Planning
Comment Number:
27897
Created By:
Mitesh Baxi
4/1/2019
Revised By:
Mitesh Baxi
4/1/2019
Title/Company:
Senior Traffic Engineering Technician / City of Wilmington
Phone/Email:
(910) 341-7893 / mitesh.baxi@wilmingtonnc.gov
Comment Attachment:
No further comments
Comment Number:
27940
Created By:
Eric Seidel
4/5/2019
Revised By:
Eric Seidel
4/5/2019
Title/Company:
Project Engineer / City of Wilmington Engineering Division
Phone/Email:
910-765-7461 / Eric.Seidel@wilmingtonnc.gov
Comment Attachment:
No Further Comments.
Comment Number:
28385
Created By:
Mitesh Baxi
7/1/2019
Revised By:
Mitesh Baxi
7/1/2019
Title/Company:
Senior Traffic Engineering Technician / City of Wilmington
Phone/Email:
(910) 341-7893 / mitesh.baxi@wilmingtonnc.gov
Comment Attachment:
07012019_StMarkMayfaireEntrance_Standardstreetlightingplan_Revised.pdf
ST MARK MAYFAIRE ENTRANCE [Plan Review] REVISED STANDARD STREET LIGHTING PLAN [City of Wilmington Street Lighting Policy]: 1. The standard streetlight shall be a DEP designated LED equivalent fixture installed within the recommended range of mounting heights for the specific fixture. The standard streetlight shall be installed on a wooden pole in areas served from overhead facilities and on a fiberglass pole in areas served from underground facilities. 2. A layout for the Standard street lighting has been provided with the review. Minimum of 2 LED 50 and 6 LED 105 street lights are required for this sub-division. Although, developers may choose to provide any extra lights or ornamental. Any installations above the criteria of Standard street lighting, will be considered as non-standard and has to conform to the City’s non-standard street lighting procedure as per the policy. 3. If non-standard lighting is desired then we will need a photometric analysis to verify that light levels in the roundabout are maintained and the light spacing on the approaches would be ½ indicated on the plan. 4. Developers shall bear any installation costs associated with streetlights, if applicable. In areas served from underground facilities, the developers shall pay the one-time underground contribution charge, if applicable. 5. The Planning, Development and Transportation Director or designee and the City Landscape Designer will coordinate plaza plantings and streetlight locations to minimize the obstruction of light by vegetation. 6. Street trees must be located a minimum of 15 feet from street lights. [CofW SD 15-17] 7. All the street light shall be installed within the public ROW. Please let me know if you have any questions or if I can be of further assistance.
Page
of
1
Results per page:
5
10
15
20
Show all Submittals