City of Wilmington - Project Tracking
Home
|
Register or Login
Home
Projects
How To
Submittal Comments for Site Plan Version 3 at Riverlights AQ Ph 4 & 5 (20170872598)
Show all Submittals
Comment Number:
27103
Created By:
Mitesh Baxi
11/20/2018
Revised By:
Mitesh Baxi
11/20/2018
Title/Company:
Senior Traffic Engineering Technician / City of Wilmington
Phone/Email:
(910) 341-7893 / mitesh.baxi@wilmingtonnc.gov
Comment Attachment:
11202018_Riverlights_AQ_Ph_4_and_5_Rev3.pdf
RIVERLIGHTS AQ PH 4 & 5 [TRC Plan Review #3] TECHNICAL STANDARDS – NEW ROADS: Pavement markings; a. Crosswalk at the intersection of Laughing Gull Terrace and Craddock Dr is not in accordance with City Standards. Revise to show both the parallel pavement markings lines. b. Site plan shows a mid-block crosswalk on Laughing Gull Terrace west of Walkfinders Court. A pedestrian (W11-2) signage and diagonal downward arrow (W16-7P) are required at the location for both side vehicular traffic. c. An advanced pedestrian (W11-2) signage is not required for the mid-block crosswalk on Laughing Gull Terrace (west of Walkfinders Court) and shall not be installed. ROUNDABOUT DESIGN: Design shows roundabout at the intersection of Laughing Gull Terrace and Tackabury Run. Please provide the roundabout details. As the City does not currently address roundabout designs in the technical standards, the design should be prepared by an engineer experienced with such and should consider geometric controls such as: • Entry angle and offset to center as appropriate • Entry, Circulating and exit speed-radius relationships • Inscribed diameter consistent with design vehicle • Truck apron consistent with design vehicle. • Consideration for Splitter Island that accommodate pedestrian refuge as room allows. • Approach and departure sight distances. • Appropriate signing and markings This list is not inclusive and submittals should provide reasoning used for each parameter. Refer FHWA, City standard, or NCDOT manuals for roundabout design standards and pavement markings. STREET LIGHTING [City of Wilmington Street Lighting Policy]: 1. A revised standard Street light plan has been provide with this review. Minimum of 28 street lights are required for this sub-division. Other comments as per initial review are still applicable. Please let me know if you have any questions or if I can be of further assistance as this development moves through the review process.
Comment Number:
27151
Created By:
Christopher J Walker
11/29/2018
Revised By:
Christopher J Walker
11/29/2018
Title/Company:
Fire Marshal / Battalion Chief / Wilmington Fire Department
Phone/Email:
910-343-3918 / chris.walker@wilmingtonnc.gov
Comment Attachment:
Nothing further from FIRE
Comment Number:
27162
Created By:
Bill McDow
11/30/2018
Revised By:
Bill McDow
11/30/2018
Title/Company:
Associate Transportation Planner / City of Wilmington
Phone/Email:
910-341-7819 / bill.mcdow@wilmingtonnc.gov
Comment Attachment:
11252018Riverlights_AQPhase4-5.pdf
RIVERLIGHTS AGE QUALIFIED PHASE 4 AND 5 [TRC Plan Review #3] TECHNICAL STANDARDS – NEW ROADS: 1. Please verify ROW widths for Craddock Drive on plans sheets, CG-100, CU-702, CU-706, CU-709, and CU-711. A few of the sections show the incorrect label for ROW width. 2. No Further Comments.
Comment Number:
27474
Created By:
Trenton Butler
1/29/2019
Revised By:
Trenton Butler
1/29/2019
Title/Company:
Staff Engineer / Engineering
Phone/Email:
(910) 341-0094 / Trent.Butler@wilmingtonnc.gov
Comment Attachment:
2019-01-28_Eng_Review-Riverlights_AQ_4and5.pdf
Page
of
1
Results per page:
5
10
15