Comments from GIS Division/Address & Street Name Management
Project Address
Overall Project Site address is approved as 2600 Independence Blvd. Addresses will be further refined as project is built out, as needed.
Development Name
The development name Barclay Centre is approved for use for this development.
Street Names
Any public street or private drive which is more than 200 feet and serves as the primary means of ingress/egress for a minimum of 4 homes/dwellings or 12 commercial structures, will be required to have a street name. The development has 1 new street, which requires an approved street name. Please submit a list of 2-4 names for review as soon as possible. Please contact us if you prefer a list of existing names to be provided, for guidance.
All street names must be approved by the City of Wilmington. Proposed street names should be submitted to one of the following City employees for approval:
Once the names are approved, they will be placed on a reserve list to be used for Barclay Centre
Approved street names must be properly labeled on all final construction plans and final plats submitted to the City. Failure to properly label the names may result in the re-submittal or re-recording of a construction plan or plat.
Street name signs for public and private streets must be erected before a Certificate of Occupancy is issued. Contact Traffic Engineering at 910.341.7888 for information about street signs for this project.
Street names may not duplicate, sound-alike, or be similar to any other street name or development name in New Hanover County (Addressing Standards and Procedures, Section 2.2.5).
Street names must be a minimum of three (3) characters and a maximum of twenty-four (24) characters in length (Addressing Standards and Procedures, Section 2.2.1 and 2.2.2).
Street names should avoid the use of special characters, such as hyphens, apostrophes, or periods (Addressing Standards and Procedures, Section 2.2.3).
Street names should avoid the use of words or syllables that may be confused with directional or street type designations (i.e. Northglen Dr or Circle Dr) (Addressing Standards and Procedures, Section 2.2.4).
Continuous streets passing from one existing subdivision to a new one should continue the same name (Addressing Standards and Procedures, Section 2.3.4).
The Addressing Standards and Procedures Manual for the City of Wilmington and New Hanover County can be found online by clicking here. Please reference this document for additional information about street suffix usage (Section 2.4.1) and other details or rules regarding street naming and addressing.
Final dwelling/unit addresses
Individual dwelling and/or unit addresses will be assigned upon final site plan approval and will be based on approved street names.
Lot or unit numbers should be labeled on site plan. Lot numbers shown on site plan should not be used as unit/dwelling address.
Please address the following issues:
- Fire apparatus access road greater than 150’ (Street A) must have an approved fire apparatus turnaround. I understand there will likely be future connectivity, however if the current lots are developed before there is connectivity emergency vehicles must have a way to turnaround without backing.
Please add the following Fire and Life Safety notes to the plan.
- Contractor shall maintain an all-weather access for emergency vehicles at all times during construction
- Landscaping or parking cannot block or impede the FDC or fire hydrants. A 3-foot clear space shall be maintained around the circumference of the hydrant and FDC