THE WOODLANDS AT ECHO FARMS DEVELOPMENT [TRC Plan Review #2]
Initial Review Note
All comments are based on adopted policy documents, specific City of Wilmington Land Development Code (CofW LDC) and City of Wilmington Technical Standards and Specifications Manual (CofWTSSM) requirements in effect at the time of this review. These have been noted after the comment as appropriate for your ease in further research. The City Engineer may administratively approve dimensional variance requests per LDC Sec. 18-348. If the Applicant feels further interpretation is in order, please contact Transportation Planning directly to discuss in additional detail. Please apply for all administrative variances in writing, an email is acceptable or this may be included on the plan set. Please see Sec. 18-348 of the Land Development Code for the information required to process a variance request.
BASE INFORMATION:
TRAFFIC IMPACT:
TECHNICAL STANDARDS – NEW ROADS:
TECHNICAL STANDARDS – ACCESS (driveway, sidewalk, and sight distance):
- Ensure proposed utilities, such as Fire Hydrants are not located in the sidewalks, (see Street L and Street J).
- Provide sidewalk to the amenity areas, Mail Kiosk, Club house, Pool and Pool house.
- The Mail Kiosk, pool and club house must be ADA accessible. Provide ADA path to these structures.
- Provide driveway connections to the Townhouses. If the curb transitions to non-vertical curb at the Townhouse driveway aprons, please show the transition area and a detail on the site details sheet.
- Public sidewalk is required on the frontage of public streets, such as the frontage near the roundabouts. Please provide sidewalk on site frontage as conditioned by the SRB.
- Distinguish between proposed and existing sidewalk(s) and provide dimensions.
- Show and apply the City’s 20’x70’ sight distance triangle at each driveway and the City’s 46’x46’ sight distance triangle at each street corner intersection on the site plan and landscaping plan. [Sec.18-529(c)(3)CofW LDC] Add a note indicating that all proposed vegetation within sight triangles shall not interfere with clear visual sight lines from 30"-10'. [Sec.18-566 CofW LDC]
TECHNICAL STANDARDS – PARKING:
TECHNICAL STANDARDS – Barrier Free Design:
31. Handicap parking spaces are not shown on the site plans.
32. Ensure to show proposed 5’ sidewalk adjacent to buildings. In areas where sidewalk is adjacent to 90 degree parking spaces provide an allowance for a 2.5’ vehicle overhang to meet ADA requirements. 4' of the sidewalk must remain clear for pedestrian use. [Chapter VII, Detail SD 15-13 CofWTSSM]
GENERAL NOTES TO ADD TO THE PLAN: (Provide Standard notes for the plan)
MISCELLANEOUS:
Please let me know if you have any questions or if I can be of further assistance as this development moves through the review process.