THE POINTE AT BARCLAY COMMERCIAL PHASE 1 [TRC Plan Review # 4]
Initial Review Note
All comments are based on adopted policy documents, specific City of Wilmington Land Development Code (CofW LDC) and City of Wilmington Technical Standards and Specifications Manual (CofWTSSM) requirements in effect at the time of this review. These have been noted after the comment as appropriate for your ease in further research.
The City Engineer may administratively approve dimensional variance requests per LDC Sec. 18-348. If the Applicant feels further interpretation is in order, please contact Transportation Planning directly to discuss in additional detail. Please apply for all administrative variances in writing, an email is acceptable or this may be included on the plan set. Please see Sec. 18-348 of the Land Development Code for the information required to process a variance request.
TECHNICAL STANDARDS – NEW ROADS:
TECHNICAL STANDARDS – ACCESS (driveway, sidewalk, and sight distance):
4. Increase the width of the 5’ sidewalk (adjacent to the angled parking along Stonecrop Drive, Barclay Pointe Blvd., and Dusty Miller Ln.) to 6.5’. The sidewalk does not have the minimum 2.5’ vehicular overhang.
5. The 20’X70’ Sight Distance Triangles were not properly shown. Ensure that the 20’ is measured from the property line behind the sidewalk. [Sec.18-529(c)(3)CofW LDC]
TECHNICAL STANDARDS – PARKING:
TECHNICAL STANDARDS – Barrier Free Design:
9. Increase the width of the proposed 5’ sidewalk, where adjacent to 60 degree parking spaces, to meet ADA requirements. Increase the sidewalk width to 6.5’ to provide the allowance for a 2.5’ vehicle overhang. [Ch. VII, SD 15-13 CofWTSSM]
Please let me know if you have any questions or if I can be of further assistance as this development continues in the review process.