No further comments
No further comments from planning
Nothing further from FIRE
THE POINT AT BARCLAY BLDG 5 and 6 [TRC Plan Review#3]
Initial Review Note
All comments are based on adopted policy documents, specific City of Wilmington Land Development Code (CofW LDC) and City of Wilmington Technical Standards and Specifications Manual (CofWTSSM) requirements in effect at the time of this review. These have been noted after the comment as appropriate for your ease in further research.
The City Engineer may administratively approve dimensional variance requests per LDC Sec. 18-348. If the Applicant feels further interpretation is in order, please contact Transportation Planning directly to discuss in additional detail. Please apply for all administrative variances in writing, an email is acceptable or this may be included on the plan set. Please see Sec. 18-348 of the Land Development Code for the information required to process a variance request.
TRAFFIC IMPACT:
The proposed Buildings 5 and 6 are required to be part of the current TIA or revised TIA. Please show the improvements for the project in the Phase 1 TIA.
TECHNICAL STANDARDS – ACCESS (driveway, sidewalk, and sight distance):
1. Dimension driveway widths and tapers. [Sec.18-529 CofW LDC]
2. Show and apply the City’s 20’x70’ sight distance triangle at each driveway and the City’s 46’x46’ sight distance triangle at each street corner intersection on the site plan and landscaping plan. [Sec.18-529(c)(3)CofW LDC] Add a note indicating that all proposed vegetation within sight triangles shall not interfere with clear visual sight lines from 30"-10'. [Sec.18-566 CofW LDC]
TECHNICAL STANDARDS – PARKING:
3. The proposed loading area is adjacent to an One-Way Drive Aisle. Vehicles will not be allowed to back into the Drive Aisle. All off street parking areas shall be arranged so that ingress and egress is by forward motion of vehicles. [Sec.18-526 CofW LDC]
4. The minimum radius is 25’ for any portion of a parking lot adjacent to a travel way (i.e. islands at the end of a parking bay) for parking that is open to the public. If the travel way will not be used for emergency service vehicles or truck traffic, you may request a tighter radius, the minimum is 15’. This request must be made in writing. [Chapter VII, Detail SD 15-13 CofWTSSM]
5. Portions of the proposed development do not appear to be in compliance with the 500’/800’ rule pertaining to the maximum length of a private drive/parking lot. [Chapter VII , C (4), pg 7-15 to 7-16 CofWTSSM]
TECHNICAL STANDARDS – Barrier Free Design:
6. The proposed handicap ramps in front of building 5 and building 6 do not appear to be standard. Please revise.
7. The sidewalk ramps adjacent to the cross walks appear to be missing. Please revise.
MISCELLANEOUS:
Permitting of business identification signage is a separate process. NCDOT/ City of Wilmington will not allow obstructions within the right of way.
Please let me know if you have any questions or if I can be of further assistance as this development moves through the review process.
THE POINT AT BARCLAY BLDG 5 and 6 [TRC Plan Review#4]
TRAFFIC IMPACT:
The WMPO will allow the proposed Buildings 5 and 6 to proceed to construction release prior to the completion of the TIA. The project will be required to meet all SRB conditions, Rezoning conditions, including installation of the S. 17th Street Multi-Use Path and Independence Blvd Sidewalk. Additionally, the WMPO may require completion of the TIA requirements for the project prior to issuance of the CO for the buildings,
Please consult Amy Kimes. PE to discuss any required improvements for the current TIA or revised TIA.
TECHNICAL STANDARDS – PARKING:
1. The proposed loading area appears to have been addressed in the SRB notes for this site.
2. The 500’/ 800’ rule pertaining to the maximum length of a private drive/ parking lot appears to have been addressed in the SRB notes.
3. No Further Comments.
|